The waste water in the collection tank is transported to the Lummela clarifier through the submersible pump. Dosing system is provided to dose the right chemicals if needed. The filter box at the top of the Lamella filters out particles larger than 5mm. After entering the sedimentation tank, the supernatant overflows and is discharged into the buffer tank for reuse. The bottom sediment sludge can be pumped out from the mud discharge port and enter the sludge treatment system in the next step.
0523-88638888
info@pwi-de.com
The waste water in the collection tank is transported to the Lummela clarifier through the submersible pump. Dosing system is provided to dose the right chemicals if needed. The filter box at the top of the Lamella filters out particles larger than 5mm. After entering the sedimentation tank, the supernatant overflows and is discharged into the buffer tank for reuse. The bottom sediment sludge can be pumped out from the mud discharge port and enter the sludge treatment system in the next step.
It is suitable for the clarification and reuse of wastewater in stone, ceramics, photovoltaic, glass processing and other industries with low SS content.
Model number | Handling capacity | Inlet flange | Discharge flange | Mud discharge flange |
U105 | 5m3/h | DN50 | DN80 | DN50 |
U110 | 10m3/h | DN80 | DN100 | DN50 |
U115 | 15m3/h | DN80 | DN100 | DN50 |
U120 | 20m3/h | DN80 | DN150 | DN50 |
U130 | 30m3/h | DN100 | DN150*2 | DN50*2 |
U150 | 50m3/h | DN100 | DN150*2 | DN*50*2 |
U175 | 75m3/h | DN100*2 | DN200*2 | DN50*2 |